Semiflexible Cable Insulated Hangers and Attachment Accessories

ERI manufactures insulated hangers for transmission line sizes from 1/2-inch through 5-inch that is compatible with semi-flexible transmission line in CommScope HELIAX® products and semi-flexible cables manufactured by RFS. ERI’s accessories also include round member and angle adapters for these hanger types.

11662 Insulated Hangers for ¼”, ⅜”, ½”, and ⅞” Cables

  • Part Number
    Description
  • 11662-3
    Insulated hanger for 1/4-inch, 3/8-inch, and 1/2-inch cables, single piece. Hangers do not include hardware kit. Use two each SC0420H0100, 1/4-20 X 1" Hex head machine bolt, or two each SC0420H0075, 1/4-20 X 3/4" Hex head machine bolt, plus two each NU0420, 1/4-20 Hex nut, and two each WL04SS, 1/4" split lock washer. Two sets required per hanger. To attach to flat tower members. Requires 9/16-inch in diameter hole. Use 12395-1, 100 Ft. Stainless Steel Wraplock Kit to attach hangers to round tower members. For use on insulated towers. Recommended maximum spacing 3.0-feet (0.9 meters).
  • 11662-2
    Insulated hanger for 7/8-inch cable, single piece. Hangers do not include hardware kit. Use two each SC0420H0100, 1/4-20 X 1" Hex head machine bolt, or two each SC0420H0075, 1/4-20 X 3/4" Hex head machine bolt, plus two each NU0420, 1/4-20 Hex nut, and two each WL04SS, 1/4" split lock washer. Two sets required per hanger. To attach to flat tower members. Requires 9/16-inch in diameter hole. Use 12395-1, 100 Ft. Stainless Steel Wraplock Kit to attach hangers to round tower members. For use on insulated towers. Recommended maximum spacing 3.0-feet (0.9 meters).

Hardware for mounting to tower member with flat surface:

  • Part Number
    Description
  • SC0420H0100
    1/4-20 X 1" Hex head machine bolt, stainless steel. Used to attach 11662-2 and 11662-3 Insulated Hanger to flat tower members. Requires 9/16-inch in diameter hole. Also requires one each NU0420 and one each WL04SS. Price shown is for each piece, two required per hanger.
  • SC0420H0075
    1/4-20 X 3/4" Hex head machine bolt, stainless steel. Used to attach 11662-2 and 11662-3 Insulated Hanger to flat tower members. Requires 9/16-inch in diameter hole. Also requires one each NU0420 and one each WL04SS. Price shown is for each piece, two required per hanger. Price shown is for each piece, two required per hanger.
  • NU0420
    1/4-20 Hex nut, stainless steel for SC0420H0100 or SC0420H0075. Price shown is for each piece, two required per hanger.
  • WL04SS
    1/4" split lock washer stainless steel for SC0420H0100 or SC0420H0075. Price shown is for each piece, two required per hanger.

Mounting to round tower member:

  • Part Number
    Description
  • 12395-1
    100 Ft. Stainless Steel Wraplock, with fasteners. Use to attach 1/4" - 7/8" insulated hangers to round members. Not to be used to attach cable or waveguide directly to towers.

33948 Insulated Hangers for 1-¼” to 5” Cables

  • Part Number
    Description
  • 33948-3
    Insulated hanger for 1-5/8-inch HELIAX, single piece. For use on insulated towers. Use Part Number 13550, Round member adapter for attaching hangers to round tower members up to 3 inches diameter or Part Number 13555A, Angle Adapter for attaching to angle tower members, up to 7/8 inches thick. Hanger includes ½-inch x 7/8-inch bolt and lock washer for attachment to flat tower members (requires 9/16-inch hole). Recommended maximum spacing 3.0-feet (0.9 meters).
  • 33948-5
    Insulated hanger for 1-1/4-inch HELIAX, single piece. For use on insulated towers. Use Part Number 13550, Round member adapter for attaching hangers to round tower members up to 3 inches diameter or Part Number 13555A, Angle Adapter for attaching to angle tower members. Hanger includes ½-inch x 7/8-inch bolt and lock washer for attachment to flat tower members (requires 9/16-inch hole). Recommended maximum spacing 3.0-feet (0.9 meters).
  • 33948-6
    Insulated hanger for 2-1/4-inch HELIAX, single piece. For use on insulated towers. Use Part Number 13550, Round member adapter for attaching hangers to round tower members up to 3 inches diameter or Part Number 13555A, Angle Adapter for attaching to angle tower members. Hanger includes ½-inch x 7/8-inch bolt and lock washer for attachment to flat tower members (requires 9/16-inch hole). Recommended maximum spacing 3.0-feet (0.9 meters).
  • 33948-2
    Insulated hanger for 3-inch HELIAX, single piece. For use on insulated towers. Use Part Number 13550, Round member adapter for attaching hangers to round tower members up to 3 inches diameter or Part Number 13555A, Angle Adapter for attaching to angle tower members. Hanger includes ½-inch x 7/8-inch bolt and lock washer for attachment to flat tower members (requires 9/16-inch hole). Recommended maximum spacing 5.0-feet (1.5 meters).
  • 33948-4
    Insulated hanger for 4-inch HELIAX, single piece. For use on insulated towers. Use Part Number 13550, Round member adapter for attaching hangers to round tower members up to 3 inches diameter or Part Number 13555A, Angle Adapter for attaching to angle tower members. Hanger includes ½-inch x 7/8-inch bolt and lock washer for attachment to flat tower members (requires 9/16-inch hole). Recommended maximum spacing 5.0-feet (1.5 meters).
  • 33948-1
    Insulated hanger for 5-inch HELIAX, single piece. For use on insulated towers. Use Part Number 13550, Round member adapter for attaching hangers to round tower members up to 3 inches diameter or Part Number 13555A, Angle Adapter for attaching to angle tower members. Hanger includes ½-inch x 7/8-inch bolt and lock washer for attachment to flat tower members (requires 9/16-inch hole). For use on insulated towers. Recommended maximum spacing 5.0-feet (1.5 meters).

13555A Insulated Angle Adapter for 1-1/4” to 5” Cables

  • Part Number
    Description
  • 13555A
    Angle Adapter, Single piece. For insulated hangers. Maximum member thickness 7/8 inches (22 mm). For 1-1/4-inch to 5-inch cable. Includes two 5/8-inch hardware attachment holes, to accommodate 1/2-inch hardware.
  • 13555A-1
    Angle Adapter Single piece. For insulated hangers. Maximum member thickness 7/8 inches (22 mm). For 1-1/4-inch to 5-inch cable. Includes two 3/4-inch hardware attachment holes, to accommodate 5/8-inch hardware.
  • 13555A-2
    Angle Adapter Single piece. For insulated hangers. Maximum member thickness 7/8 inches (22 mm). For 1-1/4-inch to 5-inch cable. Includes two 7/16-inch hardware attachment holes, to accommodate 3/8-inch hardware.

13550 Insulated Round Adapter for 1-1/4” to 5” Cables

  • Part Number
    Description
  • 13550
    Round member adapter for attaching hangers to round tower members up to 3 inches diameter, includes 1/2-inch x 1-1/4-inch hanger attachment bolt and nut. For 5-inch HELIAX and for insulated hangers for 1-1/4-inch to 5-inch. Single piece.